Engineered Building Solutions
  • Company
  • Team
  • Contact Us
  • Store Locator
  • Products

    Prolam

    Beams

    Prolam

    Posts

    Prolam

    Crib Wall

  • Technical

    Prolam

    Product Data & Specifications

    Prolam

    Span Tables

    Prolam

    Certifications

    Prolam

    Alternative Charts

    Prolam

    Online Learning Portal

    Prolam

    FAQ

    Prolam

    Quality Assurance

    Prolam

    Installation of Prolam

    Prolam

    Fixing Details

    Prolam

    Videos

    Prolam

    Glossary of terms

    Prolam

    Trade Links

  • Why Prolam
  • Projects
  • PLX20®
  • Leadtimes
Prolam Specifier
  • Products

    Prolam

    Beams

    Prolam

    Posts

    Prolam

    Crib Wall

  • Technical

    Prolam

    Product Data & Specifications

    Prolam

    Span Tables

    Prolam

    Certifications

    Prolam

    Alternative Charts

    Prolam

    Online Learning Portal

    Prolam

    FAQ

    Prolam

    Quality Assurance

    Prolam

    Installation of Prolam

    Prolam

    Fixing Details

    Prolam

    Videos

    Prolam

    Glossary of terms

    Prolam

    Trade Links

  • Why Prolam
  • Projects
  • PLX20®
  • Leadtimes
  • Prolam Specifier
  • Company
  • News
  • Case Studies
  • Contact Us
  • Store Locator
  • Specifiers Corner
  • FAQ

H5 Laminated Posts

FAQ Categories

  • General FAQ
  • H5 Laminated Posts
  • Laminated Beams
  • Prolam Specifier

Are H5 laminated posts certified for in ground use?

Yes. Prolam is leading the way with H5 laminated structural in-ground posts.

Codemarked for NZBC Compliance in B1 and B2, it means you can use Prolam in-ground posts with more confidence than ever.

 

Do I have to seal the portion of post that goes in ground?

When using the posts in-ground, the portion of the post that is to be in-ground must be sealed with a moisture-resistant coating prior to installation.

This can be sealed with the same paint or stain as the above-ground portion of the post.

What do I have to seal the in-ground portion with?

Typically the same sealer is used.

Can I use H5 posts in-ground for structural use?

Yes. Prolam posts are 'Codemark' certified for inground structural use.

How much does a Prolam post weigh?

The weight of Prolam PL8 & PL12 H5 post is around 550 kg's per cube. For example, the weight of a 135x135 3.6m is around 36 kg. E.g. 0.135 x 0.135 x 3.6 x 550 = 36.09 kg